Print Report | Back to Test Summary

Testing Report for 2021-08-04-37-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: ASCP
EFIS: ASCP
Project ID: 44444
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-04-37
TL Number from the TL Form:
Sample Submitted By Organization: Western Emulsions, Inc. - White City Emulsion
Sample Organization Contact: (208) 589-8608
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 8/4/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/4/2021
The quantity of what the sample constitutes: 2 cans split sample
A brief description of the sample: Asphalt binder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: WESTERN EMULSIONS WHITE CITY OR

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: Western Emulsions - White City Emulsion Plant - White City OR
Multigrade: Yes
Multigrade Type: PG 64-16 / PG 64-10

Test Information

DIME Test ID: 2021-08-04-37-7
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Date Tested: 8/4/2021
Verified Date: 9/2/2021
Submitted By Organization: Western Emulsions, Inc. - White City Emulsion
Organization Address: 7701 11th St,
Organization City: White City
Organization State: OR
Organization Zipcode: 97503
Organization Email: ehubert@idahoasphalt.com
Organization Phone: (208) 589-8608
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Is a normal test obtainable?: Yes
Number of replicates tested: Three
Ductility of test #1 (D1): 100 cm
Ductility of test #2 (D2): 100 cm
Ductility of test #3 (D3): 101 cm
Ductility of sample: 100 cm