Print Report | Back to Test Summary

Testing Report for 2021-08-12-38-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080F5444
EFIS: 0818000209
Project ID: 215224
QA Service Level: 2
DIST-CO-RTE-PM: 08-RIV-91-17.4/18.9
Work Description: Operational and safety improvements by constructing a portion of the Ultimate SR?91 CIP Project on WB SR?91 from Green River Road to SR?241 to alleviate traffic congestion in this area (ORA Post Mile R17.4 to R18.9, RIV Post Mile R0.0 to R0.6).
Location Description: The 91 COP consists of the following project components: adding a general purpose (GP) lane approximately 2 miles in length in the WB direction on SR?91 from Green River Road to SR?241.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Denise Sostrum
Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2021-08-12-38
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 8/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/30/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0507-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona

Material Information

Performance Grade: PG 64-28 M
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-08-12-38-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 8/31/2021
Verified Date: 8/31/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Phase: Original binder
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 70.0 degree
Dynamic Shear, G*/sin(δ): 2.15 kPa