Print Report | Back to Test Summary

Testing Report for 2021-08-20-31-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024F2204
EFIS: 0212000073
Project ID: 212775
QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-58.7/61.9
Work Description: REPLACE STRUCTURAL CONCRETE BRIDGE AND CULVERTS AND PLACE HMA.
Location Description: TRINITY COUNTY NEAR TRINITY CENTER FROM 58.7 MILES NORTH OF PREACHER MEADOWS ROAD TO 60.7 MILES SOUTH OF EL DORADO WAY
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mandhir Grewal
Structure Rep.: Mike Sears

Sample Information

DIME Sample ID: 2021-08-20-31
TL Number from the TL Form:
Sample Submitted By Organization: Universal Precast Concrete
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 8/20/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/20/2021
The quantity of what the sample constitutes: 2
A brief description of the sample: conc cylinder
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Precast Concrete

Material Information

The concrete mix design number: PC78A0E1
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 001256
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: back of truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2021-08-20-31-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 8/27/2021
Verified Date: 8/30/2021
Submitted By Organization: Universal Precast Concrete
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Apparent mass of submerged cylinder 1: 8.4 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Compressive strength (to nearest 10 psi): 4460 psi
Maximum load on cylinder 1: 56810 lb
Maximum load on cylinder 2: 55270 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Serial number of delivery ticket, if available: no data