Print Report | Back to Sample Detail

Sample Record for 2021-08-16-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215446 DEA: 120S4504 EFIS: 1220000070 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-39-8.5/11.7
Work Description: COLD PLANE AC PVMT AND PLACE RHMA
Location Description: ORANGE COUNTY IN WESTMINSTER AND STANTON FROM ROUTE 22/39 SEPARATION TO STARR STREET
Contractor Name: RJ Noble Company
Contractor Address: 15505 East Lincoln Avenue, Orange, CA 92865
Resident Engineer: Lieu Pham Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-16-28
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/16/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/24/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0495-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R J Noble Orange

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2021-08-16-28-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 08/26/2021
Date Tested: 08/26/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Block Penetration
Block Penetration 35 0.1 mm
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2021-08-16-28-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 08/26/2021
Date Tested: 08/25/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 61 C
Softening Point Sample 2 61 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2021-08-16-28-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 08/26/2021
Date Tested: 08/26/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 67 mm
Ball Penetration (P1) 0 mm
Final Dial reading (F2) 70 mm
Ball Penetration (P2) 0 mm
Final Dial reading (F3) 69 mm
Ball Penetration (P3) 0 mm
Resilience 1 33 %
Resilience 2 30 %
Resilience 3 31 %
Average Resilience 31 %
Minutes Reaction no data