Print Report | Back to Test Summary

Testing Report for 2021-08-16-3-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030H4804
EFIS: 0315000198
Project ID: 214175
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99-0.1/1.6,11.8/21.6
Work Description: COLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location Description: SACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Sushma Lee
Structure Rep.: Kim Noonan

Sample Information

DIME Sample ID: 2021-08-16-3
TL Number from the TL Form: na
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/16/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/20/2021
The quantity of what the sample constitutes: 1200
A brief description of the sample: 3/4 x 3" A325 Rocap Assy.
From where was the sample collected: Fabricator
Laboratory sample identification: na
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): TT0144318
Heat Number(s): 100103861, 166575, B56001
Nut Mfg. Lot Number(s): 23994-166575
Washer Mfg. Lot Number(s): D9304
Bolt Specification: A325
Bolt Length(s): 3"
Nut Specification: A563-DH
Washer Specification: F436
Finish: Mechanical Galvanize
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: BM0903
Rocap Test Requirement(s): na
Lubricant Requirements(s): Wax and Dye

Test Information

DIME Test ID: 2021-08-16-3-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Date Tested: 8/26/2021
Verified Date: 8/31/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Bolt Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Wedge Angle (deg) Comments Tested By
1B BM0903 0.7500 48251 214.63 10.00 A325 Wedge Tensile spaine
UTM: 450kip
Temperature: no data