STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 030H5204 Cty ED Rte 50 PM 0.0/80.4

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Juanah Koker

Date Reported:

08/25/2021

Address:

TL Number:

79376

City:

Project Name: INSTALL CMS, CAMERA SYSTEMS AND TMS ELEMENTS.

Prime Contractor: TIM PAXIN'S PACIFIC EXCAVATION INC

Sample Taken Date:

07/28/2021

Mix Design:

CT072CR8WA

Contractor: Unknown

Location: EL DORADO COUNTY AT VARIOUS LOCATIONS FROM THE SACRAMENTO COUNTY LINE TO CALIFORNIA/NEVADA STATE LINE

Structure unique identifier:

Structure name: Location 20 CIDH CMS

Location of Pour:


The following testing has been tested in accordance with:

ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0212.69412653251.01
24.0212.69423803339.01
34.0212.694311933971

DIME Test ID: 2021-07-28-4-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3330
Age of specimen: 7 days
Certified By: Spencer Adams


ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0212.69521774111.01
24.0212.69563004436.01
34.0312.765614044011

DIME Test ID: 2021-07-28-4-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4320
Age of specimen: 28 days
Certified By: Spencer Adams



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing