Print Report | Back to Test Summary

Testing Report for 2021-04-21-30-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: AML-CEM
EFIS: AML-CEM
Project ID: 8801
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-21-30
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 4/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/21/2021
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: Silica Fume
From where was the sample collected: Source
Laboratory sample identification: CM215110
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RED Industries

Material Information

Brand: RED Industrial Products
Mill: Mississippi Silicon
Type of Cementitious Material: Silica Fume

Test Information

DIME Test ID: 2021-04-21-30-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Date Tested: 8/23/2021
Verified Date: 8/23/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day test @ 1:35
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Will control cubes be used per ASTM C311?: yes
Age of specimen: 7 days
The amount of flow : 116 %
The amount of water used : 48.5 %
Compressive strength of 1st specimen : 5782 psi
Compressive strength of 2nd specimen: 6122 psi
Compressive strength of 3rd specimen : 5681 psi
Average Compressive strength (to nearest 10 psi): 5860 psi
Average Compressive strength (to nearest 10 psi) control group: 5020 psi
Strength Activity Index of Portland Cement per ASTM C109: 117 %