Print Report | Back to Test Summary

Testing Report for 2021-08-10-26-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 11288834
EFIS: 1117000088
Project ID: 214937
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-11,125,905-various
Work Description: CONSTRUCT CONCRETE BRIDGE, PAVEMENT, BARRIER, AND INSTALL LIGHTING. HPLUL-6211(133) SR-125 SB to WB SR-905
Location Description: SAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Carlos Covarrubias
Structure Rep.: Michael Charak

Sample Information

DIME Sample ID: 2021-08-10-26
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 8/10/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/13/2021
The quantity of what the sample constitutes: 18
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10976
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0573821, S0574421-2, S0583421, S0574321-2
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Information

DIME Test ID: 2021-08-10-26-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Date Tested: 8/23/2021
Verified Date: 8/23/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Heat Number Coil Area (sqin) Peak Load (lbf) Load at EUL (lbf) Chord Modulus (Msi) Elongation (in) Tested By
S0573821 S379770-4 0.216 59569 55338.4 28.3 1.78 bewing
UTM: 120kip
Temperature: 72 f