Print Report | Back to Test Summary

Testing Report for 2021-08-17-6-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 031F1504
EFIS: 0300001101
Project ID: 215296
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-50-R7.7/R9.5
Work Description: PLACE HMA, RHMA, AGGREGATE BASE AND FIBER OPTIC SYSTEM.
Location Description: SACRAMENTO COUNTY IN AND NEAR RANCHO CORDOVA FROM BRADSHAW ROAD OVERCROSSING TO MATHER FIELD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ephrem Teweldeburhan
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-17-6
TL Number from the TL Form: 850277
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 8/17/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/18/2021
The quantity of what the sample constitutes: 1 CAN
A brief description of the sample: Rubber
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Perkins Batch Plant

Material Information

Asphalt modifier supplier: marathon
Performance Grade: PG 64-16
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-08-17-6-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Date Tested: 8/22/2021
Verified Date: 8/23/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified : Pass

Submitted Test Results

Temperature: 25 C
Final Dial reading (F1): 72 mm
Ball Penetration (P1): no data
Final Dial reading (F2): 70 mm
Ball Penetration (P2): no data
Final Dial reading (F3): 73 mm
Ball Penetration (P3): 1 mm
Resilience 1: 28 %
Resilience 2: 30 %
Resilience 3: 28 %
Average Resilience: 29 %