Print Report | Back to Test Summary

Testing Report for 2021-08-14-3-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081C8504
EFIS: 0813000047
Project ID: 215109
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-0.0/5.8
Work Description: ROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS.
Location Description: RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Osama Abdalla
Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2021-08-14-3
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 8/14/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/17/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0476-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCA-Lake Elsinore

Material Information

Performance Grade: PG 64-28 M
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-08-14-3-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 8/19/2021
Verified Date: 8/27/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Phase: Original binder
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 64.7 degree
Dynamic Shear, G*/sin(δ): 2.52 kPa