Print Report | Back to Sample Detail

Sample Record for 2020-09-02-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214492 DEA: 033F5404 EFIS: 0313000136 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99,160-4.5/5.7,R44.5
Work Description: FURNISH PRECAST PRESTRESSED CONCRETE SLAB & PLACE STRUCTURAL CONCRETE.
Location Description: SACRAMENTO COUNTY NEAR GALT ON ROUTE 99 FROM NORTH OF MINGO ROAD TO SOUTH OF ARNO ROAD OVERCROSSING AND IN SACRAMENTO ON ROUTE 160 AT AMERICAN RIVER BRIDGE
Contractor Name: BROSAMER & WALL, INC.
Contractor Address: 5000 Marsh Drive, Suite 300, Conord, CA 94520
Resident Engineer: Mohssen Ghassemi Structure Rep.: Chris Quon

Sample Information

DIME Sample ID: 2020-09-02-26
TL Number from the TL Form:
Sample Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Sample Organization Contact: (559) 292-2188
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 09/02/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/03/2020
The quantity of what the sample constitutes: 4 cylinders
A brief description of the sample: 1615759 PCC
From where was the sample collected: Job Site
Laboratory sample identification: 20-192 090220
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CEMEX Lodi

Material Information

The concrete mix design number: 1615759
The truck number from where the sample was collected: 10069093
The batch plant ticket number from where the sample was collected: 42535495
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Truck
Where the material sample would have been placed if not sampled: unknown
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2020-09-02-26-1
Test Method: ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 08/17/2021
Date Tested: 09/02/2020
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4.5 inch

Test 2 of 3

DIME Test ID: 2020-09-02-26-2
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 08/17/2021
Date Tested: 09/02/2020
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air Content 1.5 %

Test 3 of 3

DIME Test ID: 2020-09-02-26-3
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/17/2021
Date Tested: 09/30/2020
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 1
Average Compressive Strength (to nearest 10) 5130 lb/in^2
Cylinder Age 28 days
Break Description of Cylinder 1 (if not 'cone') 2