Sample Record for 2021-08-10-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215109 DEA: 081C8504 EFIS: 0813000047
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-0.0/5.8
Work Description: ROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS.
Location Description: RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 38000 MONROE STREET, INDIO, CA 92203
Resident Engineer: Osama Abdalla Structure Rep.: Ryan Kash (Reports)
Sample Information
DIME Sample ID: 2021-08-10-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 08/10/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2021
The quantity of what the sample constitutes: Heat 100100654
A brief description of the sample: 150 ksi All Thread Bar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name: RW388R, RW466R, RW472R, RW474R, RW536R
The fabricator/manufacturer/facility name: Williams Form Engineering San Diego
Material Information
Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Plain
Rebar Size: #11
Nut Specification for Threaded Bar: A29
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100100654
Nut Heat Number(s): 75081194
Bar Lot Number: NA
Nut Lot Number: Heat Code 36E5D
Coupler Heat Number(s): NA
Coupler Grade: NA
Test Results
Test 1 of 5
DIME Test ID: 2021-08-10-1-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/17/2021
Date Tested: 08/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar & Nut Heat #75081194 (36E5D)
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 1 | ASTM A722 Type II Deformed Bar 1 3/8 : 36mm | 100100654 | 1.515 | 159827.15 | 151.39 | 0 | 50.2 | Bar & Nut Heat #75081194 (36E5D) | fsaylor |
| |
Temperature
|
72 f
|
UTM
|
2000kip
|
Test 2 of 5
DIME Test ID: 2021-08-10-1-2
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/17/2021
Date Tested: 08/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar & Nut Heat #75081194 (36E5D) Nut Stripped off
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 2 | ASTM A722 Type II Deformed Bar 1 3/8 : 36mm | 100100654 | 1.58 | 164306.16 | 150.17 | 3.64 | 100 | Bar & Nut Heat #75081194 (36E5D) Nut Stripped off | fsaylor |
| |
Temperature
|
72 f
|
UTM
|
2000kip
|
Test 3 of 5
DIME Test ID: 2021-08-10-1-3
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/17/2021
Date Tested: 08/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Grip Pull
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 3 | ASTM A722 Type II Deformed Bar 1 3/8 : 36mm | 100100654 | 1.58 | 165378.86 | 164.95 | 7.27 | 100 | Bar Grip Pull | fsaylor |
| |
Temperature
|
72 f
|
UTM
|
2000kip
|
Test 4 of 5
DIME Test ID: 2021-08-10-1-4
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 08/17/2021
Date Tested: 08/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
12 mils
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
First Bar Mean
|
11.24
|
Second Bar Mean
|
10.52
|
Total mean value
|
10.88
|
Test 5 of 5
DIME Test ID: 2021-08-10-1-5
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 08/17/2021
Date Tested: 08/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
14
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|