Print Report | Back to Test Summary

Testing Report for 2021-07-29-29-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 101J1204
EFIS: 1018000150
Project ID: 215341
QA Service Level: 1
DIST-CO-RTE-PM: 10-MER-33-R0.0/L5.7
Work Description: COLD PLANE ASPHALT CONCRETE AND PLACE HOT MIX ASPHALT.
Location Description: MERCED COUNTY IN AND NEAR DOS PALOS FROM FRESNO COUNTY LINE TO 0.1 MILE NORTH OF EAST JUNCTION ROUTE 152
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Stewart
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-07-29-29
TL Number from the TL Form: 034238
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 7/29/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/11/2021
The quantity of what the sample constitutes: 2 CanS
A brief description of the sample: PG64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Santa Fe Winton

Material Information

Asphalt modifier supplier: NATIONAL BLENDING
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 4

Test Information

DIME Test ID: 2021-07-29-29-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Date Tested: 8/16/2021
Verified Date: 8/16/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Determination: Unworked Penetration
Unworked Penetration: 35 0.1 mm