Print Report | Back to Test Summary

Testing Report for 2015-08-13-6-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 04014104
EFIS: 0413000133
Project ID: 209417
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-80-2.6
Work Description: CONSTRUCT SFOBB MAINTENANCE FACILITIES - PHASE II
Location Description: IN ALAMEDA COUNTY ON ROUTE 80 AT THE SAN FRANCISCO BAY BRIDGE MAINTENANCE YARD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Behzad Halali
Structure Rep.: Hazzaa El-Mahmoud

Sample Information

DIME Sample ID: 2015-08-13-6
TL Number from the TL Form: 000017
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 8/13/2015
Date that the sample was received by the laboratory/organization performing the testing: 8/17/2015
The quantity of what the sample constitutes: Cylinders
A brief description of the sample: concrete
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: unknown

Material Information

The concrete mix design number: Unknown
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Warehouse B1 stem wall east
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-08-13-6-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 9/24/2015
Verified Date: 9/24/2015
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 5480 psi
Maximum load on cylinder 1: 154851 lb
Maximum load on cylinder 2: 155689 lb
Compressive strength of cylinder 1: 5477.6 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 5487.8 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 42 days
Age of specimen in hours: no data