Print Report | Back to Test Summary

Testing Report for 2021-08-03-17-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081H4904
EFIS: 0817000059
Project ID: 215494
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-18-31.9/38.5
Work Description: COLD PLANE AC PAVEMENT AND OVERLAY WITH HMA (TYPE A).
Location Description: SAN BERNARDINO COUNTY FROM 0.1 MILE EAST OF HILLTOP CONNECTOR TO 0.5 MILE EAST OF SIBERIA CREEK TRAIL
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nhan Nguyen
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-03-17
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 8/3/2021
Date that the sample was received by the laboratory/organization performing the testing: 8/5/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0445-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Matich-Rialto

Material Information

Performance Grade: PG 64-28 M
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: Matich-Rialto
Asphalt Binder Supplier: Marathon Petroleum Co. LP - Bakersfield CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-08-03-17-4
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Date Tested: 8/6/2021
Verified Date: 8/9/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Is viscosity reading in cP/Pa-s?: Pa-s
Time of test: 7:48 HH:MM
Test Temperature: 135 C
Speed: 50 rpm
Spindle size: 21 in
Torque: 76 %
Viscosity reading #1 (A) : 0.757 Pa-s
Viscosity reading #2 (B) : 0.765 Pa-s
Viscosity reading #3 (C): 0.764 Pa-s