Print Report | Back to Test Summary

Testing Report for 2015-08-14-17-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07215954
EFIS: 0700001835
Project ID: 209141
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-0.0/7.6
Work Description: WIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location Description: LOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Thang Ton
Structure Rep.: Amare Tsagie

Sample Information

DIME Sample ID: 2015-08-14-17
TL Number from the TL Form: Unknown
Sample Submitted By Organization: G3 Quality, Inc. - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 8/14/2015
Date that the sample was received by the laboratory/organization performing the testing: 8/15/2015
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: jobsite

Material Information

The concrete mix design number: G3-15-STR-001
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant: Security Paving Plant
The fabricator/manufacturer designation for the sample: Set 12
A detailed description of where the material sample was collected: CIDH Pile SW 313
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-08-14-17-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 8/21/2015
Verified Date: 10/23/2015
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 2890 psi
Maximum load on cylinder 1: 78820 lb
Maximum load on cylinder 2: 84740 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data