Print Report | Back to Sample Detail

Sample Record for 2021-07-06-45

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212914 DEA: 031E0604 EFIS: 0312000068 QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-70-15.5/16.5
Work Description: SIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location Description: NEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
Contractor Name: MCM Construction
Contractor Address: PO Box 620, North Highlands, Ca 95660
Resident Engineer: Manoharan Selvendran Structure Rep.: Travis Christie

Sample Information

DIME Sample ID: 2021-07-06-45
TL Number from the TL Form: 930967
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 07/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/26/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: PG64-16
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Northwest Oil

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2021-07-06-45-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 07/28/2021
Date Tested: 07/28/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 30 0.1 mm

Test 2 of 3

DIME Test ID: 2021-07-06-45-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 07/28/2021
Date Tested: 07/28/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 73 C
Softening Point Sample 2 73 C
Bath Liquid USP glycerin
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2021-07-06-45-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 07/28/2021
Date Tested: 07/27/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 76 mm
Ball Penetration (P1) 3 mm
Final Dial reading (F2) 72 mm
Ball Penetration (P2) 0 mm
Final Dial reading (F3) 75 mm
Ball Penetration (P3) 3 mm
Resilience 1 27 %
Resilience 2 28 %
Resilience 3 28 %
Average Resilience 28 %
Minutes Reaction no data