Print Report | Back to Test Summary

Testing Report for 2021-07-22-4-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 042A3324
EFIS: 0414000039
Project ID: 215231
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-84-10.8/18
Work Description: NILES CANYON SAFETY PROJECT
Location Description: ALAMEDA CREEK BR OH (33-0034) BRIDGE RAIL REPLACEMENT, 2,060 LF; AND STONYBROOK CREEK BRIDGE (SLAB BRIDGE)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Davinder Singh
Structure Rep.: Jordan Jarosz

Sample Information

DIME Sample ID: 2021-07-22-4
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 7/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/23/2021
The quantity of what the sample constitutes: 150
A brief description of the sample: #6 with A2 Lenton Couplers
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: C and N Reinforcing

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Erico
Intermediate Assembler or Fabricator:
Rebar Size: #6
Coupler Model: A2 Lenton Couplersx
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): L9760
Rebar Heat Number(s): 3500018139
Rebar Size 2 : 6

Test Information

DIME Test ID: 2021-07-22-4-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Date Tested: 7/28/2021
Verified Date: 7/28/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Servce Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples Tested: 1
Sample Number of Cycles Size Mfg. Lot Number(s) Slip (inch) Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 No. 6/19mm 1 0 0.44 42427 96424 Servce Splice fsaylor
UTM: 400kip
Temperature: 72.00 f
Halo ID: