Print Report | Back to Test Summary

Testing Report for 2021-07-21-17-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 061A5304
EFIS: 0620000052
Project ID: 215630
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-198-26.3/26.8
Work Description: COLD PLANE PAVEMENT, RESURFACE WITH HMA AND MODIFY SIGNAL.
Location Description: FRESNO COUNTY NEAR COALINGA FROM 0.5 MILE WEST OF ROUTE 5 TO ROUTE 198/5 SEPARATION
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Anourack Khamoraseuth
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-07-21-17
TL Number from the TL Form: c039907
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 7/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/23/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: PG 70-10
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite - Colinga

Material Information

Performance Grade: PG 70-10
Modified: No
Lot number: 1
Sublot number: 4
Tank number:
Time of sample:
HMA Supplier: Granite - Coalinga
Asphalt Binder Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-07-21-17-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 7/27/2021
Verified Date: 7/28/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO - DSR
Test Result Compliance: does not comply
Additional Comments When Verified :

Submitted Test Results

Phase: RTFO residue
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.201 kPa
Phase Angle (δ) (for the 10 cycles): 89.0 degree
Complex Modulus (G*) (for the 10 measurements): 2.006 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 2.01 kPa