Print Report | Back to Sample Detail

Sample Record for 2021-07-13-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214945 DEA: 051G1304 EFIS: 0514000110 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-1-M29.9/49.2
Work Description: COLD PLANE AC PAVEMENT, PLACE RHMA-G & HMA (TYPE A).
Location Description: SANTA BARBARA COUNTY NEAR SANTA MARIA FROM CALIFORNIA BOULEVARD TO ROUTE 166
Contractor Name: CAL PORTLAND CONSTRUCTION
Contractor Address: 1625 E Donovan Road, Santa Maria, CA 93454
Resident Engineer: Thomas Peterson Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-07-13-19
TL Number from the TL Form: 210713C
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 07/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: World Oil

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1537
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2021-07-13-19-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 07/23/2021. The corrected test ID is: 2021-07-13-19-5
Reason: retested

Test 2 of 5

DIME Test ID: 2021-07-13-19-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 07/23/2021. The corrected test ID is: 2021-07-13-19-4
Reason: retested

Test 3 of 5

DIME Test ID: 2021-07-13-19-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 07/23/2021
Date Tested: 07/23/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 78 mm
Ball Penetration (P1) 2 mm
Final Dial reading (F2) 79 mm
Ball Penetration (P2) 4 mm
Final Dial reading (F3) 79 mm
Ball Penetration (P3) 5 mm
Resilience 1 24 %
Resilience 2 25 %
Resilience 3 26 %
Average Resilience 25 %
Minutes Reaction no data

Test 4 of 5

DIME Test ID: 2021-07-13-19-4
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 07/23/2021
Date Tested: 07/23/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
The test was superseded from test ID: 2021-07-13-19-2
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 70 C
Softening Point Sample 2 70 C
Bath Liquid USP glycerin
Minutes Reaction no data

Test 5 of 5

DIME Test ID: 2021-07-13-19-5
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 07/23/2021
Date Tested: 07/23/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
The test was superseded from test ID: 2021-07-13-19-1
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 37 0.1 mm