Print Report | Back to Test Summary

Testing Report for 2021-07-14-18-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 031E0604
EFIS: 0312000068
Project ID: 212914
QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-70-15.5/16.5
Work Description: SIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location Description: NEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Manoharan Selvendran
Structure Rep.: Travis Christie

Sample Information

DIME Sample ID: 2021-07-14-18
TL Number from the TL Form: c597108
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 7/14/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/21/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: PG64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Hollwood

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 1

Test Information

DIME Test ID: 2021-07-14-18-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Date Tested: 7/23/2021
Verified Date: 7/23/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

ASTM Thermometer used?: C
Softening Point Sample 1: 65 C
Softening Point Sample 2: 65 C
Bath Liquid: USP glycerin