Print Report | Back to Test Summary

Testing Report for 2021-07-07-20-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081K8404
EFIS:
Project ID: 215534
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-247-39.0/42.0&46.0/70.0
Work Description: RUBBERIZED HMA AND HIGH DENSITY POLYURETHANE MATERIAL INJECTION.
Location Description: SAN BERNARDINO COUNTY AT LUCERNE VALLEY FROM 0.5 MILE SOUTH OF CAMP ROCK ROAD TO 0.1 MILE SOUTH OF MIDWAY AVENUE AND FROM 1.1 MILES SOUTH OF HOLMES ROAD TO 1.2 MILES NORTH OF STODDARD VALLEY ROAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-07-07-20
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 7/7/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/20/2021
The quantity of what the sample constitutes: 1Quart
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Refining Company- Mojave, CA

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-07-07-20-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Date Tested: 7/22/2021
Verified Date: 8/11/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

ASTM Thermometer used?: C
Softening Point Sample 1: 64 C
Softening Point Sample 2: 63 C
Bath Liquid: freshly boiled distilled water