Print Report | Back to Sample Detail

Sample Record for 2021-07-16-18

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214402 DEA: 010E7704 EFIS: 0115000009 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-R17.9/87.8
Work Description: STRENGTHEN 2 BRIDGES.
Location Description: HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
Contractor Name: Freyssinet Inc
Contractor Address: 44880 Falcon Place, Suite 100, Sterling, VA 20166
Resident Engineer: Joaquin Rodriguez Structure Rep.: Ryan Duran

Sample Information

DIME Sample ID: 2021-07-16-18
TL Number from the TL Form: C835668
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/16/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2021
The quantity of what the sample constitutes: 5205 assemblies total
A brief description of the sample: 1" A325 HDG fastener assemblies
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: various
The fabricator/manufacturer/facility name: CK Johnson Industries

Material Information

Rocap Number(s): 773472-448326D-214483
Heat Number(s): Bolt 10449580 Nut 100106332 Washer 214483
Nut Mfg. Lot Number(s): 448326D
Washer Mfg. Lot Number(s): 214483
Bolt Specification: A325 Hvy Hex HDG
Bolt Length(s): 7 1/2"
Nut Specification: F563 DH HDG
Washer Specification: F436 HDG
Finish: Hot Dip Galvanized
Diameter/Size: 1" dia
Bolt Mfg. Lot Number: 773472
Rocap Test Requirement(s): yes
Lubricant Requirements(s): yes

Test Results

Test 1 of 6

DIME Test ID: 2021-07-16-18-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/22/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
17734721.000087368388.6310.00A325fsaylor
UTM 450kip
Temperature no data

Test 2 of 6

DIME Test ID: 2021-07-16-18-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/22/2021
Date Tested: 07/22/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 7A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 773472
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA LE
Size 1 in
Bolt Length 7.5 in
Gage Type Pass

Test 3 of 6

DIME Test ID: 2021-07-16-18-3
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/22/2021
Date Tested: 07/22/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 7A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 448326D
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 1 in
Gage Type Pass

Test 4 of 6

DIME Test ID: 2021-07-16-18-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/22/2021
Date Tested: 07/22/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 7A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 773472
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA LE
Size 1 in
Bolt Length 7.5 in
Measurement Average 3.12 mils

Test 5 of 6

DIME Test ID: 2021-07-16-18-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/22/2021
Date Tested: 07/22/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 7A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 448326D
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 1 in
Bolt Length no data in
Measurement Average 3.1 mils

Test 6 of 6

DIME Test ID: 2021-07-16-18-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/22/2021
Date Tested: 07/22/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 7A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 214483
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 3.93 in
Bolt Length no data in
Measurement Average 3.93 mils