Print Report | Back to Test Summary

Testing Report for 2021-05-13-37-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024E4504
EFIS: 0200020286
Project ID: 212496
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS,MOD-139,299-VAR
Work Description: PLACE HMA, REPLACE DRAINAGE, CULVERT, ELECTRICAL AND LIGHTING SYSTEMS.
Location Description: LASSEN AND MODOC COUNTIES ON ROUTE 139 AT 0.1 MILE NORTH OF LASSEN COUNTY LINE AND ON ROUTE 299 AT VARIOUS LOCATONS FROM 0.4 MILE WEST OF BOYD HILL LOOKOUT ROAD TO 0.6 MILE EAST OF COUNTY ROAD 87
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mike Zdenek
Structure Rep.: Chris Brace

Sample Information

DIME Sample ID: 2021-05-13-37
TL Number from the TL Form: 765845
Sample Submitted By Organization: CT D02 - North Region Materials Lab
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 5/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 5/14/2021
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 3/4-inch Type A HMA (eq. PG 64-28 M)
From where was the sample collected: Manufacturer
Laboratory sample identification: D78795
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction and Materials - Shaw Pit Facility - Lookout, CA

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-05-13-37-6
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Date Tested: 5/19/2021
Verified Date: 7/20/2021
Submitted By Organization: CT D02 - North Region Materials Lab
Organization Address: 1657 Riverside Dr,MS-83
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 6.8 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 7.8 mm
Stripping Inflection Point (Wheel A): 14460
Stripping Inflection Point (Wheel B): 10976