Testing Report for 2021-07-13-3-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080F5434
EFIS: 0817000239
Project ID: 215188
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-I-15,SR-91-6.1-7.6
Work Description: I-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location Description: Junction of I-15 and SR-91 in Corona, CA
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Roy Fisher
Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2021-07-13-3
TL Number from the TL Form:
Sample Submitted By Organization: CT METS QASI - Los Angeles Design Build Field Laboratory
Sample Organization Contact: (619) 204-7248
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 7/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/16/2021
The quantity of what the sample constitutes: 3 strand packs
A brief description of the sample: ASTM A416 0.6" x 270 KSI strand
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering Golden, CO

Material Information

Comments:
Reel/Coil/Pack Number(s): T300456-4 and T300456-9 or T300456-2
Number of Coils: 3
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): T0218017-2
Mfg. Lot Number(s): Lot 1
Manufacturer(s): Sumiden Wire

Test Information

DIME Test ID: 2021-07-13-3-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Date Tested: 7/20/2021
Verified Date: 7/20/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Heat Number Coil Area (sqin) Peak Load (lbf) Load at EUL (lbf) Chord Modulus (Msi) Elongation (in) Tested By
218017 T300456-4 0.219 59131 54345.8 27.9 1.89 bewing
UTM: 120kip
Temperature: 72 f
Extensometers: no data