Sample Record for 2021-07-01-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214532 DEA: 07316904 EFIS: 0715000227
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-1,2,5,10-Various
Work Description: TUNNEL LIGHTING, MESSAGE SIGN SYSTEMS, RETAINING WALL & BUILDING WORK.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS
Contractor Name: ALDRIDGE ELECTRIC, INC.
Contractor Address: 2369 Yates Ave, Commerce, CA 90040
Resident Engineer: Frank Shin Structure Rep.: Frank Lotfi
Sample Information
DIME Sample ID: 2021-07-01-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/01/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/09/2021
The quantity of what the sample constitutes: 29
A brief description of the sample: 1” (8) x 2” ASTM A325 Bolt
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Saint Louis Screw and Bolt
Material Information
Rocap Number(s):
Heat Number(s): 100894992
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM A325
Bolt Length(s):
Nut Specification: NA
Washer Specification: NA
Finish: Mechanically Galvanized
Diameter/Size: 1" (8) x 2"
Bolt Mfg. Lot Number: BM0787
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 3
DIME Test ID: 2021-07-01-1-1
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/19/2021
Date Tested: 07/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BM0787
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA SL
|
Size
|
1 in
|
Bolt Length
|
2 in
|
Gage Type
|
Pass
|
Test 2 of 3
DIME Test ID: 2021-07-01-1-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/19/2021
Date Tested: 07/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BM0787
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA SL
|
Size
|
1 in
|
Bolt Length
|
2 in
|
Measurement Average
|
4.58 mils
|
Test 3 of 3
DIME Test ID: 2021-07-01-1-3
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/19/2021
Date Tested: 07/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BM0787
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA SL
|
Size
|
1 in
|
Bolt Length
|
2 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.6
|
Spacing
|
Ok
|