Sample Record for 2021-06-28-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214562 DEA: 040J7104 EFIS: 0414000029
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-1.8/4.4
Work Description: RAISE BRIDGE AND PLACE STRUCTURAL CONCRETE.
Location Description: SOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS
Contractor Name: BROSAMER & WALL, INC.
Contractor Address: 1777 Oakland Blvd., Suite 300, Walnut Creek, CA 94596
Resident Engineer: Quang Tran Structure Rep.: Mohan Ayadurai
Sample Information
DIME Sample ID: 2021-06-28-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Acceptance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 06/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2021
The quantity of what the sample constitutes: 33
A brief description of the sample: 1.5"x12"x16" and 1.5"x12"x12"
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 19236-1
Material/Compound/Elastomer ID: 19236
Samples Representing: 33 pads
Description (size): 1.5"x12"x16" and 1.5"x12"x12"
Comments:
Description (Number of Shims): 3
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: 19236-1
Test Results
Test 1 of 4
DIME Test ID: 2021-06-28-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 07/19/2021
Date Tested: 07/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
50
|
Reading #2
|
50
|
Reading #3
|
50
|
Reading #4
|
50
|
Reading #5
|
50
|
Mean
|
50
|
Test 2 of 4
DIME Test ID: 2021-06-28-2-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 07/19/2021
Date Tested: 07/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.086
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2748.1 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.085
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2656.45 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.082
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2634.33 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2656.5 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2021-06-28-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 07/19/2021
Date Tested: 07/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.079
|
Sample 1 Tear Strength
|
235.3
|
Sample 2 Median Thickness
|
0.08
|
Sample 2 Tear Strength
|
233.9
|
Sample 3 Median Thickness
|
0.086
|
Sample 3 Tear Strength
|
235
|
Median of the Tear Strength Values
|
235 lb/in
|
Test 4 of 4
DIME Test ID: 2021-06-28-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 07/19/2021
Date Tested: 07/19/2021
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: