Print Report | Back to Test Summary

Testing Report for 2021-07-02-7-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080C2514
EFIS: 0816000076
Project ID: 212112
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2021-07-02-7
TL Number from the TL Form:
Sample Submitted By Organization: G3 Quality, Inc. - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Per Request
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 7/2/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/15/2021
The quantity of what the sample constitutes: 32
A brief description of the sample: #5 HRC
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC Rebar
Coupler Manufacturer: HRC
Intermediate Assembler or Fabricator:
Rebar Size: #5
Coupler Model: HRC 500 / 510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): HRC 500 Heat 74120293 HRC 510 Heat 7312029
Rebar Heat Number(s): 4107214
Rebar Size 2 :

Test Information

DIME Test ID: 2021-07-02-7-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Date Tested: 7/15/2021
Verified Date: 7/19/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples Tested: 1
Sample Number of Cycles Size Mfg. Lot Number(s) Slip (inch) Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 No. 5/16mm 1 0 0.31 28880 93160 OK Necking fsaylor
UTM: 400kip
Temperature: 72.00 f
Halo ID: