Testing Report for 2021-07-08-4-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080C2514
EFIS: 0816000076
Project ID: 212112
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2021-07-08-4
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 7/8/2021
Date that the sample was received by the laboratory/organization performing the testing: 7/13/2021
The quantity of what the sample constitutes: 35000 lbs
A brief description of the sample: A615 Gr80
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 80
Threaded Bar Type: Deformed
Rebar Size: #8
Nut Specification for Threaded Bar: N/A
System Manufacturer: Nucor Skyline
Epoxy Coating Color: NA
Threaded Bar Application: Soil Nail
Coating Standards: Uncoated
Bar Heat Number(s): 3700019312, 3700019313, 3700019310, 370001930
Nut Heat Number(s): N/A
Bar Lot Number: N/A
Nut Lot Number: N/A
Coupler Heat Number(s): N/A
Coupler Grade: N/A

Test Information

DIME Test ID: 2021-07-08-4-4
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 7/14/2021
Verified Date: 7/14/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A615 Bar Blue Paint
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Mfg Lot Area (sqin) Tensile Strength (psi) Stress at Offset (psi) Total Elongation (%) Comments Tested By
No.8/25mm 0.79 117375 86117 0 A615 Bar Blue Paint bewing
Temperature: 72 f
UTM: 400kip