Testing Report for 2021-06-16-16-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 033F99U4
EFIS: 0319000311
Project ID: 214618
QA Service Level: 1
DIST-CO-RTE-PM: 03-SUT-99-39.2/41.4
Work Description: WIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location Description: SUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Dwayne Grandy
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-06-16-16
TL Number from the TL Form: 706335
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 6/16/2021
Date that the sample was received by the laboratory/organization performing the testing: 6/21/2021
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: PG58-22
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Benicia

Material Information

Performance Grade: PG 58-22
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: DeSilva Gates
Asphalt Binder Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-06-16-16-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Date Tested: 7/14/2021
Verified Date: 7/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Minimum test bath temperature at 240 s: -12.0 C
Maximum test bath temperature at 240 s: -11.9 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): no data
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 981.0 mN
Beam deflection 60.0 s: 0.664 µm
Measured Stiffness Modulus 60.0 s: 119.000 mPa
Estimated Stiffness Modulus 60.0 s: 119.000 mPa
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.355