Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H3424 Cty SAC Rte 99 PM 22.6 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Howard Giang |
Date Reported: |
07/13/2021 |
|
Address: |
TL Number: |
197317 |
||
City: |
||||
Project Name: REPLACE BRIDGE DECK WITH PRESTRESSED CONCRETE BOX GIRDER. |
||||
Prime Contractor: BRIDGEWAY CIVIL CONSTRUCTORS, INC. |
||||
Sample Taken Date: |
06/15/2021 |
Mix Design: |
CT550 |
|
Contractor: Unknown |
Location: SACRAMENTO COUNTY IN SACRAMENTO AT 21ST AVENUE UNDERCROSSING |
|||
Structure unique identifier: |
||||
Structure name: Concrete barrier Type 60 MG and Type 60 MGC |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.96 | 27.9 | 186567 | 6687.0 | 1 |
2 | 5.96 | 27.9 | 184168 | 6601.0 | 1 |
DIME Test ID: 2021-06-15-9-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6640
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing