Sample Record for 2021-07-01-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215231 DEA: 042A3324 EFIS: 0414000039 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-84-10.8/18
Work Description: NILES CANYON SAFETY PROJECT
Location Description: ALAMEDA CREEK BR OH (33-0034) BRIDGE RAIL REPLACEMENT, 2,060 LF; AND STONYBROOK CREEK BRIDGE (SLAB BRIDGE)
Contractor Name: Bay Cities Paving & Grading
Contractor Address: 1450 Civic Ct. BLDG B #400, Concord CA, 94520
Resident Engineer: Eddie Dike Structure Rep.: Oanh Bui

Sample Information

DIME Sample ID: 2021-07-01-11
TL Number from the TL Form: C670958
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 07/01/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2021
The quantity of what the sample constitutes: 4
A brief description of the sample: HRC 555 End Anchors
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor HRC

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 3500016143
Head Manufacturer Lot Number(s): 1
Rebar Size: #6
Headed Bar Model Name: HRC 555
Size of Head: Reduced Size - 4x
Head Connection Type: Inertia Weld
Head Shape: Circular
Rebar Manufacturer: Nucor
Head Manufacturer: HRC
Head Fabricator: HRC
Material Standard Code: ASTM A706
Headed Bar Unique ID:

Test Results

Test 1 of 3

DIME Test ID: 2021-07-01-11-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/07/2021
Date Tested: 07/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.444338298596OK Neckingfsaylor
Temperature 72 f
UTM 400kip

Test 2 of 3

DIME Test ID: 2021-07-01-11-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/07/2021
Date Tested: 07/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.444351498894OK Neckingfsaylor
Temperature 72 f
UTM 400kip

Test 3 of 3

DIME Test ID: 2021-07-01-11-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/07/2021
Date Tested: 07/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.444344498736OK Neckingfsaylor
Temperature 72 f
UTM 400kip