Print Report | Back to Test Summary

Testing Report for 2021-06-29-16-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 043G4424
EFIS: 0412000042
Project ID: 210037
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-R5.6/7.6
Work Description: WEST SPAN DAMPER BRACKET A325 BOLT TESTING
Location Description: SFOBB WEST SPAN
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tom Larwin
Structure Rep.: Sergio Gomez

Sample Information

DIME Sample ID: 2021-06-29-16
TL Number from the TL Form: C835665
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 6/29/2021
Date that the sample was received by the laboratory/organization performing the testing: 6/30/2021
The quantity of what the sample constitutes: 76
A brief description of the sample: F3129 A325 Bolts Nut & washers
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bay Bolt

Material Information

Rocap Number(s): 254501 25452 25453
Heat Number(s):
Nut Mfg. Lot Number(s): 23891-75063117 432090A
Washer Mfg. Lot Number(s): 0618-877
Bolt Specification: F3125 A325
Bolt Length(s): 5, 6, 6.5
Nut Specification: A563
Washer Specification: F436
Finish: F2329
Diameter/Size: 1.125
Bolt Mfg. Lot Number: 758391 770370 L847B1
Rocap Test Requirement(s):
Lubricant Requirements(s): Blue Green

Test Information

DIME Test ID: 2021-06-29-16-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Date Tested: 6/30/2021
Verified Date: 6/30/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Sample No.: 3A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: L847B1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: 1.125 in
Bolt Length: 6.5 in
Measurement Average: 3.39 mils