Print Report | Back to Test Summary

Testing Report for 2021-06-29-14-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024F5404
EFIS: 0213000004
Project ID: 213337
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-5-R15.3/R16.5
Work Description: BRIDGE REPLACEMENT - SOUTHBOUND ONLY
Location Description: SISKIYOU COUNTY NEAR WEED FROM 0.1 MILE SOUTH OF DEETZ ROAD UNDERCROSSING TO 0.6 MILE NORTH OF BLACK BUTTE OVERHEAD 02-0004L
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Jeff Steppat
Structure Rep.: Andy O'Sullivan

Sample Information

DIME Sample ID: 2021-06-29-14
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 6/29/2021
Date that the sample was received by the laboratory/organization performing the testing: 6/30/2021
The quantity of what the sample constitutes: 150 Couplers
A brief description of the sample: #11 Lenton couplers
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: PSG

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Lenton
Intermediate Assembler or Fabricator:
Rebar Size: #11
Coupler Model: Lenton STD A2
Coating Standards: ASTM A775 epoxy
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): L9289
Rebar Heat Number(s): 1201027613
Rebar Size 2 :

Test Information

DIME Test ID: 2021-06-29-14-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Date Tested: 6/30/2021
Verified Date: 6/30/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples Tested: 1
Sample Number of Cycles Size Mfg. Lot Number(s) Slip (inch) Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 No. 11/36mm 1 0 1.56 132530 84955 Service Splice fsaylor
UTM: 2000kip
Temperature: 72.00 f
Halo ID: