Print Report | Back to Test Summary

Testing Report for 2020-11-23-6-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: AML-CEM
EFIS: AML-CEM
Project ID: 8801
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-11-23-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 11/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/23/2020
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Type II Cement
From where was the sample collected: Source
Laboratory sample identification: CM205042
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

Brand: Cemex
Mill: Vissai
Type of Cementitious Material: Type II/V Cement

Test Information

DIME Test ID: 2020-11-23-6-6
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Date Tested: 12/21/2020
Verified Date: 6/23/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Specific gravity: 3.15
Water Content: 235
The amount of flow (In percent): 85 %
The amount of water used (In percent): 67.14 %
Net Weight of Sample: 848.4 grams
Air Content: 7 %