Project Information

DEA: 081C38U4
EFIS: 0817000196
Project ID: 213707
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Elvira Lenart
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-06-15-14
TL Number from the TL Form: 53RR
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 6/15/2021
Date that the sample was received by the laboratory/organization performing the testing: 6/18/2021
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 1012-53RR
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: coffman

Material Information

The concrete mix design number: 1906-17
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 3
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: job
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2021-06-15-14-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 6/22/2021
Verified Date: 6/22/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength (to nearest 10 psi): 2820 psi
Maximum load on cylinder 1: 79395 lb
Maximum load on cylinder 2: 79280 lb
Compressive strength of cylinder 1: 2826.5 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 2822.4 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data