Print Report | Back to Sample Detail

Sample Record for 2021-06-08-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212324 DEA: 033F5104 EFIS: 0313000020 QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-20-R18.1/R20.1
Work Description: Construct bridge, realign curve & widen shoulders.
Location Description: Construction on state highway in Yuba County near Smartsville from the Yuba River Bridge to 0.3 mile east of Smartsville Road.
Contractor Name: Flatiron West, Inc.
Contractor Address: 2100 Goodyear Road, Benicia, CA 94510
Resident Engineer: Aaron Chamberlin Structure Rep.: Brent Bullard

Sample Information

DIME Sample ID: 2021-06-08-15
TL Number from the TL Form: 930926
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 06/08/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2021
The quantity of what the sample constitutes: 2 Cans
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Marathon

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number: 1
Sublot number: 3
Tank number:
Time of sample:
HMA Supplier: Teichert
Certified Asphalt Supplier: Marathon Petroleum Co. LP - Elk Grove CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2021-06-08-15-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 06/17/2021
Date Tested: 06/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 177.183 grams
Mass of empty container #2 178.810 grams
Mass of container #1 before test (m1i) 212.349 grams
Mass of container #2 before test (m2i) 213.835 grams
Mass of container #1 after test (m1f) 212.213 grams
Mass of container #2 after test (m2f) 213.702 grams
Average mass change -0.383 percent

Test 2 of 5

DIME Test ID: 2021-06-08-15-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/17/2021
Date Tested: 06/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications ORIG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.168 kPa
Phase Angle (δ) (for the 10 cycles) 87.4 degree
Complex Modulus (G*) (for the 10 measurements) 1.398 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 1.40 kPa

Test 3 of 5

DIME Test ID: 2021-06-08-15-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/17/2021
Date Tested: 06/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.397 kPa
Phase Angle (δ) (for the 10 cycles) 83.9 degree
Complex Modulus (G*) (for the 10 measurements) 3.970 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 3.99 kPa

Test 4 of 5

DIME Test ID: 2021-06-08-15-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/17/2021
Date Tested: 06/16/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 40.230 kPa
Phase Angle (δ) (for the 10 cycles) 51.4 degree
Complex Modulus (G*) (for the 10 measurements) 4022.061 kPa
Test Temperature (Specimen 1) 28.0 C
(G*) x sin(δ)= 3143 kPa

Test 5 of 5

DIME Test ID: 2021-06-08-15-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 06/17/2021
Date Tested: 06/16/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s -6.1 C
Maximum test bath temperature at 240 s -6.0 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) 0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 0.0 mN
Deflection at time 0.0 s 0.000 µm
Load at time 0.5 s 0.0 mN
Deflection at time 0.5 s 0.000 µm
Load at 60.0 s 965.0 mN
Beam deflection 60.0 s 0.818 µm
Measured Stiffness Modulus 60.0 s 95.100 mPa
Estimated Stiffness Modulus 60.0 s 95.500 mPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.389