Print Report | Back to Test Summary

Testing Report for 2021-06-07-18-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: STOCK EFIS: STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-06-07-18
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/07/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2021
The quantity of what the sample constitutes: 12
A brief description of the sample: A449 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KT Bolt

Material Information

Rocap Number(s):
Heat Number(s): 75071839
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A449
Bolt Length(s): 6"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: .625"
Bolt Mfg. Lot Number: 54703-1
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2021-06-07-18-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 06/16/2021
Date Tested: 06/15/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A449 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1BUNC 5/8 0.2263024113413381012154027468A449 Wedge Tensile
UTM 400kip
Temperature 72