Testing Report for 2015-07-13-11-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 040120T4
EFIS: 0400000027
Project ID: 7285
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-12.6/13.9
Work Description: CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Bill Howe
Structure Rep.: Mehran Ardakanian

Sample Information

DIME Sample ID: 2015-07-13-11
TL Number from the TL Form:
Sample Submitted By Organization: CT YBITS2 - Oakland Field Laboratory
Sample Organization Contact: (510) 286-4247
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 7/13/2015
Date that the sample was received by the laboratory/organization performing the testing: 8/6/2015
The quantity of what the sample constitutes: 2 cyliners
A brief description of the sample: Abutment 11 Wall
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: Abutment 11 Wall
Structure name: EB Onramp
The fabricator/manufacturer/facility name: Central

Material Information

The concrete mix design number: D101C5E1
The truck number from where the sample was collected: 1215
The batch plant ticket number from where the sample was collected: 18050237
Concrete batch plant: 12
The fabricator/manufacturer designation for the sample: MCM Construction
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-07-13-11-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 8/10/2015
Verified Date: 8/10/2015
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4780 psi
Maximum load on cylinder 1: 133115 lb
Maximum load on cylinder 2: 137277 lb
Compressive strength of cylinder 1: 4708.7 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 4855.9 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data