Print Report | Back to Test Summary

Testing Report for 2021-04-12-61-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081G0004
EFIS: 0815000107
Project ID: 214339
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-95-14.5/35.6
Work Description: CONSTRUCT CONCRETE/RSP APRONS
Location Description: RIVERSIDE COUNTY AT VARIOUS LOCATIONS FROM 4 MILES NORTH OF PALO VERDE DAM ROAD TO 0.6 MILE SOUTH OF SAN BERNARDINO COUNTY LINE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Hien Vu
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-12-61
TL Number from the TL Form:
Sample Submitted By Organization: Pro-Cast Products Inc.
Sample Organization Contact: (909) 793-7602
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 4/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/13/2021
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ProCast Products

Material Information

The concrete mix design number: PRO18051
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: TT
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2021-04-12-61-3
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 5/10/2021
Verified Date: 6/10/2021
Submitted By Organization: Pro-Cast Products Inc.
Organization Address: 27417 E. Third St., PO Box 602,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: chad@procast.us
Organization Phone: (909) 793-7602
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 7540 psi
Maximum load on cylinder 1: 212900 lb
Maximum load on cylinder 2: 213540 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: no data
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data