Project Information

DEA: 021J4404
EFIS: 0220000079
Project ID: 215250
QA Service Level: 1
DIST-CO-RTE-PM: 02-MOD-299-20.0/23.1,23.5/24.5,33.5/37.5
Work Description: ASPHALT RUBBER CHIP SEAL.
Location Description: MODOC COUNTY AT VARIOUS LOCATIONS FROM 1.8 MILES WEST OF ROUTE 139 TO 0.3 MILE WEST OF RATTLESNAKE CREEK BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tofael Anwar
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-14-27
TL Number from the TL Form: 823526
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 5/14/2021
Date that the sample was received by the laboratory/organization performing the testing: 6/1/2021
The quantity of what the sample constitutes: 2 cans
A brief description of the sample: TEST Asphalt Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Albina - Klamath Falls, OR

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: S.T. Rhoades
Asphalt Binder Supplier: Albina Asphalt - Klamath Falls Plant - Klamath Falls OR
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-05-14-27-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 6/8/2021
Verified Date: 6/9/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Phase: PAV residue
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 32.314 kPa
Phase Angle (δ) (for the 10 cycles): 53.6 degree
Complex Modulus (G*) (for the 10 measurements): 3231.036 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 2601 kPa