Print Report | Back to Test Summary

Testing Report for 2021-05-26-16-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081K1904
EFIS: 0818000207
Project ID: 215359
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-16.1/169.4
Work Description: REMOVE, PREPARE AND FURNISH POLYESTER CONC OVERLAY & BRIDGE DECK.
Location Description: SAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT VARIOUS LOCATIONS FROM CAJON CREEK TO MICRO DITCH.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Thanh Pham
Structure Rep.: Monty Navarro

Sample Information

DIME Sample ID: 2021-05-26-16
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 5/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 5/27/2021
The quantity of what the sample constitutes: 2 Bags Coldfeec Agg., 11 Bags Agg., 2 Bags Rap
A brief description of the sample: PSUE 3/4 " HMA-A-SP R15, 1.0% LSM
From where was the sample collected: Manufacturer
Laboratory sample identification: 0311A-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond Materials

Material Information

Source Identification (SMARA or name of Pit): 91-36-0046, 91-36-0106
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A-SP R15
The fabricator/manufacturer designation for the sample:
The plant number: 300154 LSM
A detailed description of where the material sample was collected: Belt Cut at Blue Diamond Victorville Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-05-26-16-9
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Date Tested: 6/2/2021
Verified Date: 6/8/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: Rap Gradation After Ignition
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 95 %
Cumulative percent passing the #4 sieve: 63 %
Cumulative percent passing the #8 sieve: 46 %
Cumulative percent passing the #16 sieve: 34 %
Cumulative percent passing the #30 sieve: 25 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 12 %
Cumulative percent passing the #200 sieve: 9 %