Print Report | Back to Test Summary

Testing Report for 2021-05-05-30-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 032F5704
EFIS: 0300020615
Project ID: 215063
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-46.3/63.5
Work Description: Replace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tad Sampson
Structure Rep.: Jimmer Ross

Sample Information

DIME Sample ID: 2021-05-05-30
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 5/5/2021
Date that the sample was received by the laboratory/organization performing the testing: 5/27/2021
The quantity of what the sample constitutes: 9
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: D S Brown

Material Information

Mfg. Lot Number(s): 4001799-3A
Material/Compound/Elastomer ID: NA
Samples Representing: 9
Description (size): 1.150 x 12 x 12
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): D S Brown
Batch Number: NA

Test Information

DIME Test ID: 2021-05-05-30-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Date Tested: 5/27/2021
Verified Date: 6/3/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of specimens tested: 3
UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.083
Sample 1 Tear Strength: 251.2
Sample 2 Median Thickness: 0.082
Sample 2 Tear Strength: 252.9
Sample 3 Median Thickness: 0.082
Sample 3 Tear Strength: 249.2
Median of the Tear Strength Values: 251.2 lb/in