Print Report | Back to Test Summary

Testing Report for 2021-05-07-13-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215163 DEA: 060X3904 EFIS: 0618000061 QA Service Level: 1
DIST-CO-RTE-PM: 06-KIN-43-0.0/3.2
Work Description: COLD PLANE PAVEMENT, PLACE HMA, RHMA AND TRAFFIC STRIPING.
Location Description: KINGS COUNTY IN AND NEAR CORCORAN FROM TULARE COUNTY LINE TO 0.1 MILE NORTH OF SANTA FE AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Cary Cruz Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-07-13
TL Number from the TL Form: C039627
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 05/07/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/13/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: asphalt binder
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refining Co Inc

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: Granite Coalinga HMA Plant
Asphalt Binder Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-05-07-13-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 06/01/2021
Date Tested: 05/19/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per standard specifications
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Minimum test bath temperature at 240 s -6.0 C
Maximum test bath temperature at 240 s -6.0 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) 0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 0.0 mN
Deflection at time 0.0 s 0.000 µm
Load at time 0.5 s 0.0 mN
Deflection at time 0.5 s 0.000 µm
Load at 60.0 s 980.0 mN
Beam deflection 60.0 s 0.435 µm
Measured Stiffness Modulus 60.0 s 182.000 mPa
Estimated Stiffness Modulus 60.0 s 181.000 mPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.391