Sample Record for 2021-05-17-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214700 DEA: 030F2804 EFIS: 0312000069
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99-7.1/9.4
Work Description: Dillard Overcrossing and McConnel Overhead
Location Description: Hwy 99, Elk Grove, CA
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4001 Bradshaw Road, Sacramento, CA 95827
Resident Engineer: Saed Masoud Structure Rep.: Chau Ha
Sample Information
DIME Sample ID: 2021-05-17-3
TL Number from the TL Form: C850180
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 05/17/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: pg64-16
From where was the sample collected: Source
Laboratory sample identification: 1550708954
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite
Material Information
Performance Grade: PG 64-16
Modified: No
Lot number: 4
Sublot number: 12
Tank number:
Time of sample: 23:59
HMA Supplier:
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: Yes
Multigrade Type:
Asphalt Binder Mix Number:
Test Results
Test 1 of 6
DIME Test ID: 2021-05-17-3-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 06/01/2021.
Reason: retested
Test 2 of 6
DIME Test ID: 2021-05-17-3-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/01/2021
Date Tested: 05/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 Standard Specifications ORIG
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.193 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
85.3 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.612 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.62 kPa
|
Test 3 of 6
DIME Test ID: 2021-05-17-3-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/01/2021
Date Tested: 05/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 Standard Specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.333 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
79.1 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
3.327 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
3.39 kPa
|
Test 4 of 6
DIME Test ID: 2021-05-17-3-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/01/2021
Date Tested: 05/26/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Test Gap
|
2 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
1.00 %
|
Stress Amplitude
|
37.431 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
48.1 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
3742.800 kPa
|
Test Temperature (Specimen 1)
|
28.0 C
|
(G*) x sin(δ)=
|
2786 kPa
|
Test 5 of 6
DIME Test ID: 2021-05-17-3-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 06/01/2021
Date Tested: 05/26/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s
|
-6.0 C
|
Maximum test bath temperature at 240 s
|
-5.9 C
|
Time of test load application
|
no data HH:MM:SS
|
File name of test data
|
no data
|
Time beam in bath
|
no data
|
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
994.0 mN
|
Beam deflection 60.0 s
|
1.149 µm
|
Measured Stiffness Modulus 60.0 s
|
69.800 mPa
|
Estimated Stiffness Modulus 60.0 s
|
69.800 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.397
|
Test 6 of 6
DIME Test ID: 2021-05-17-3-6
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 06/01/2021
Date Tested: 05/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
0.000 grams
|
Mass of empty container #2
|
0.000 grams
|
Mass of container #1 before test (m1i)
|
206.590 grams
|
Mass of container #2 before test (m2i)
|
202.084 grams
|
Mass of container #1 after test (m1f)
|
206.453 grams
|
Mass of container #2 after test (m2f)
|
201.943 grams
|
Average mass change
|
-0.395 percent
|