Print Report | Back to Test Summary

Testing Report for 2021-04-08-44-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081C38U4
EFIS: 0817000196
Project ID: 213707
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Elvira Lenart
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-08-44
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 4/8/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/12/2021
The quantity of what the sample constitutes: 2 HMA boxes
A brief description of the sample: 3/4" HMA-A-SP R24 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0210A-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: California Commercial Asphalt - Coachella

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-04-08-44-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Asphalt Binder Content)
Date Tested: 4/13/2021
Verified Date: 5/24/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Asphalt Binder Content: 4.40 %
Correction Factor (Percent by mass of HMA Specimen): no data