Print Report | Back to Test Summary

Testing Report for 2021-05-10-5-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 060X3904
EFIS: 0618000061
Project ID: 215163
QA Service Level: 1
DIST-CO-RTE-PM: 06-KIN-43-0.0/3.2
Work Description: COLD PLANE PAVEMENT, PLACE HMA, RHMA AND TRAFFIC STRIPING.
Location Description: KINGS COUNTY IN AND NEAR CORCORAN FROM TULARE COUNTY LINE TO 0.1 MILE NORTH OF SANTA FE AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Cary Cruz
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-10-5
TL Number from the TL Form: C039612
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 5/10/2021
Date that the sample was received by the laboratory/organization performing the testing: 5/13/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: asphalt binder
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refining Co Inc

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: Granite Coalinga HMA Plant
Asphalt Binder Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-05-10-5-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 5/19/2021
Verified Date: 6/1/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Phase: RTFO residue
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.233 kPa
Phase Angle (δ) (for the 10 cycles): 88.3 degree
Complex Modulus (G*) (for the 10 measurements): 2.331 kPa
Test Temperature: 64.0 C
Dynamic Shear, G*/sin(δ): 2.33 kPa