Print Report | Back to Test Summary

Testing Report for 2021-04-22-12-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030F2504
EFIS: 0300000075
Project ID: 213406
QA Service Level: 1
DIST-CO-RTE-PM: 03-YOL,SAC-80-R11.1/R11.7,M0.0/M0.5
Work Description: SAC RIVER BOH (BRYTE BEND)
Location Description: SACRAMENTO AND YOLO COUNTIES IN WEST SACRAMENTO AND SACRAMENTO FROM 0.1 MILE WEST OF REED AVENUE UNDERCROSSING TO 0.1 MILE EAST OF SACRAMENTO RIVER BRIDGE AND OVERHEAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ephrem Teweldeberhan
Structure Rep.: Brent Bullard

Sample Information

DIME Sample ID: 2021-04-22-12
TL Number from the TL Form: 169759
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 4/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/26/2021
The quantity of what the sample constitutes: 2 Cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 22-0026L
Structure name: Type 824A STA 231/68 1/2 to STA 234/08 1/2
The fabricator/manufacturer/facility name: Teichert Perkins

Material Information

The concrete mix design number: Z5605153
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2021-04-22-12-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 5/20/2021
Verified Date: 5/20/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.96 in
Average diameter of cylinder 2: 5.96 in
Cross sectional area of cylinder 1: 27.9 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Compressive strength (to nearest 10 psi): 3850 psi
Maximum load on cylinder 1: 108670 lbf
Maximum load on cylinder 2: 106237 lbf
Compressive strength of cylinder 1: 3895.0 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 3808.0 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data