Print Report | Back to Test Summary

Testing Report for 2021-05-13-7-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120K0214
EFIS: 1214000096
Project ID: 214355
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-12.4/14.5
Work Description: South County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY
Location Description: ORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Farid Zokai
Structure Rep.: Imad Karam

Sample Information

DIME Sample ID: 2021-05-13-7
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 5/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 5/14/2021
The quantity of what the sample constitutes: (4) LENTON FORM SAVER (Sleeve-Tapered Thread)
A brief description of the sample: LENTON FORM SAVER (Sleeve-Tapered Thread)
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coreslab Structures L A Inc

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC Steel Arizona
Coupler Manufacturer: Erico nVent
Intermediate Assembler or Fabricator: Coreslab Structures L A Inc
Rebar Size: #8
Coupler Model: ST-17-05
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator: NA
Coupler Component Heat/Lot Number(s): L9814
Rebar Heat Number(s): 4102817
Rebar Size 2 : 8

Test Information

DIME Test ID: 2021-05-13-7-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Date Tested: 5/14/2021
Verified Date: 5/18/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples Tested: 1
Sample Number of Cycles Size Mfg. Lot Number(s) Slip (inch) Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 No. 8/25mm 1 0 0.79 77659 98302 Service Splice fsaylor
UTM: 400kip
Temperature: 72.00 f
Halo ID: