Print Report | Back to Test Summary

Testing Report for 2021-05-13-8-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120K0214
EFIS: 1214000096
Project ID: 214355
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-12.4/14.5
Work Description: South County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY
Location Description: ORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Farid Zokai
Structure Rep.: Imad Karam

Sample Information

DIME Sample ID: 2021-05-13-8
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 5/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 5/14/2021
The quantity of what the sample constitutes: (8) nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar
A brief description of the sample: nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coreslab Structures L A Inc

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 4102817
Head Manufacturer Lot Number(s): L9805 L9766
Rebar Size: #8
Headed Bar Model Name: 9TT 17 02
Size of Head: Full Size - 9x
Head Connection Type: Taper Threaded
Head Shape: Circular
Rebar Manufacturer: CMC Steel Arizona
Head Manufacturer: ERICO International Corporation nVent
Head Fabricator: nVent Lenton
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2021-05-13-8-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 5/14/2021
Verified Date: 5/18/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Head Pull Off
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
1 0.79 80379 101746 Head Pull Off fsaylor
Temperature: 72 f
UTM: 400kip